Products & Services

 
Home  \ Products & Services  \  Lister Petter \ Genset Series \ T 50Hz  \ 

LATLR Gensets

 
LATLR Gensets
 

LATLR 15(A)*, LATLR 24(A)

50 Hz; 1500 r/min; power outputs: 9.4 - 20.2 kVA
Air cooled gensets for up to 2000 hours unattended running

Basic Characteristics

• 50Hz, 1500 r/min
• Lister Petter T Series air cooled, direct injection, naturally aspirated diesel engine (two or three cylinders)
• open set (LATLR) or acoustic set (LATLRA)

Standard Features

• control system with electronic digital control module
• single bearing, 4-pole brushless alternator
• 55-litre base mounted lubrication oil tank with inspection cover and dipstick
• 5 micron Lister Petter bypass oil filter
• fuel return fittings for bulk fuel systems
• zirconium phosphated powder coated base plate with forklift pockets
• bunded base retaining 110% of all fluids
• anti vibration mountings
• 12V starter battery and leads
• mechanical governing
• emergency stop button (lock-down type)
• flywheel mounted cooling fan
• operators’ handbook
• electrical diagrams

 

Power Outputs

1500 r/min

Model Engine Rating Single Phase Three Phase
220V *
230V *
240V *
380/220V *
400/230V *
415/240V *
kVA kWe kVA kWe
LATLR 15(A) TR2 PRP 8.9 8.9 12.5 10.0
ESP 9.4 9.4 13.1 10.5
LATLR 24(A) ** TR3 PRP 14.5 14.5 19.4 15.5
ESP 15.2 15.2 20.3 16.2

* Other voltages are available on request

** ESP ratings are not available for the LATLR 24A (acoustic canopied) generating set, this set is limited to operating at a maximum of 40°C

 
‹ Back